Silicone rubber insulated cable should not be rated greater than 50 watts/metre. Insulation temperature must not be allowed to rise above 150°C. Silicone rubber insulated cable is supplied on 100. There is a tolerance of + 5% on resistance.
- The table provides average ratings for different temperature requirements of 15 watts/metre, 25 watts/ metre and 35 watts/metre.
- Normal refers to anti-condensation heaters for normal temperature refrigerated doors (drink coolers etc.)
- Low refers to anti-condensation heaters for low temperature cabinets (frozen food).
- Freezer refers to heaters that prevent ice build-up around cool room doors etc. It is important to note that higher outputs may be required for this type of application. The maximum operating temperature should not exceed 150°C.
Technical Information:
SRG60
- Cable Required - Normal Temp: 7.8 - 8.3mtrs.
- Cable Required - Low Temp Cabinets: 6 - 7mtrs.
- Cable Required - Freezer: 5 - 6mtrs.